Known Limitations

Known Limitations/Issues with DRAGEN Protein Quantification v3.0 Software:

  • Only supports 96 samples per PlateBarcode for a single analysis.

  • SampleIDs must be unique prior to uploading SomaSeq Automation System output files to BaseSpace Sequence Hub run planner tool.

  • Calibrators provided with MultiMatrix runs are retained in the ADAT but are not used by autolaunch normalization. Explore DRAGEN Protein Quantification: Advanced Normalization Options in ICM to use matched sample-type calibrators.

  • Runs from different assay versions (v1 and v2) of SomaSeq Discovery cannot be combined in the same analysis.

  • If multiple kit types are present in the same flowcell, separate ADATs are generated for each kit type.

  • DRAGEN Protein Quantification v3.0 only supports the following Probe Pool lot combinations: CSF and MultiMatrix kits require Probe Pool AA; Plasma and Serum kits require Probe Pool AB.

  • DRAGEN Report specification page for MultiMatrix incorrectly displays the specification range for QC Check (PlatformSpecificQCCheckTailPercent) as 0.8 - 1.2; the correct range applied by the software is 0.4 - 1.6.

Known Limitations/Issues with Local Sample Sheet Generation Tool v3.0:

  • Sample sheet must be saved as "CSV Comma-Delimited" and not "CSV UTF-8".

  • Tool only supports starting from SomaSeq Automation System File v2, supporting SomaSeq Discovery v2 Assay.