> For the complete documentation index, see [llms.txt](https://help.multiomics.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.multiomics.illumina.com/dragen-protein-quantification/counting-and-normalization/metrics-appendix.md).

# Metrics Appendix

## Sample Level Metrics

Sample level metrics are found in the sample/row-level metadata in the ADAT.

<table><thead><tr><th width="136">Metric</th><th>ADAT Field</th><th>Applied To</th><th>Applies To (Kit Type)</th><th>Threshold</th><th>Impact to Sample</th></tr></thead><tbody><tr><td>Minimum SOMAmer Read Count</td><td>SOMAmerReads; SOMAmerReads_PassFlag</td><td>Non-Blank Samples</td><td>Plasma, Serum, CSF</td><td>SOMAmerReads > 10 million</td><td>PASS/FLAG</td></tr><tr><td>Maximum SOMAmer Normalized Read Count</td><td>SOMAmerNormReads; SOMAmerNormReads_PassFlag</td><td>Blank Samples</td><td>All kits</td><td>SOMAmerNormReads &#x3C; 20 million reads</td><td>PASS/FLAG</td></tr><tr><td>Hybridization QC</td><td>HybQC; HybQC_PassFlag; HybQC_Ref (header); HybQC_Delta (header)</td><td>Non-Blank Samples</td><td>All kits</td><td>HybQC ≤ HybQC_Delta</td><td>PASS/FLAG</td></tr><tr><td>Hybridization Normalization</td><td>HybNorm_1_ScaleFactor; HybNorm_PassFlag</td><td>Non-Blank Samples</td><td>Plasma, Serum</td><td>0.4 ≤ HybNorm_1_ScaleFactor ≤ 2.5</td><td>PASS/FLAG</td></tr><tr><td>Hybridization Normalization</td><td>HybNorm_1_ScaleFactor; HybNorm_PassFlag</td><td>Calibrator and QC Samples only</td><td>MultiMatrix</td><td>0.4 ≤ HybNorm_1_ScaleFactor ≤ 2.5</td><td>PASS/FLAG</td></tr><tr><td>Hybridization Normalization</td><td>HybNorm_1_ScaleFactor; HybNorm_PassFlag</td><td>Calibrator and QC Samples</td><td>CSF</td><td>0.4 ≤ HybNorm_1_ScaleFactor ≤ 2.5</td><td>PASS/FLAG</td></tr><tr><td>Hybridization Normalization</td><td>HybNorm_1_ScaleFactor; HybNorm_PassFlag</td><td>Customer Samples</td><td>CSF</td><td>0.2 ≤ HybNorm_1_ScaleFactor ≤ 5.0</td><td>PASS/FLAG</td></tr><tr><td>Internal Reference Median Normalization</td><td>MedNormInt_&#x3C;Dilution>_ScaleFactor; MedNormInt_PassFlag</td><td>Individual Blank and Calibrator samples, split by dilution group</td><td>All kits</td><td>0.4 ≤ MedNormInt_&#x3C;Dilution>_ScaleFactor ≤ 2.5</td><td>PASS/FLAG</td></tr><tr><td>External Reference Median Normalization</td><td>MedNormExt_&#x3C;Dilution>_ScaleFactor; MedNormExt_PassFlag</td><td>Individual non-control and QC samples, split by dilution group</td><td>Plasma, Serum, CSF</td><td>0.4 ≤ SF ≤ 2.5 (Plasma, Serum, CSF QC); 0.125 ≤ SF ≤ 8.0 (CSF samples)</td><td>PASS/FLAG</td></tr><tr><td>Cross-Plate Internal Median Normalization</td><td>CrossPlateMedNormInt_ScaleFactor; CrossPlateMedNormInt_PassFlag</td><td>MultiMatrix Samples</td><td>MultiMatrix</td><td>0.4 ≤ CrossPlateMedNormInt_ScaleFactor ≤ 2.5</td><td>PASS/FLAG</td></tr><tr><td>Row Check</td><td>RowCheck_PassFlag</td><td>All samples</td><td>All kits</td><td>PLATE_FAIL if the sample is on a plate that received a FAIL. Otherwise, PASS if all Pass Flags in this row are PASS and FLAG if not.</td><td>PASS/FLAG/PLATE_FAIL</td></tr></tbody></table>

> **MultiMatrix kit notes:**
>
> * MultiMatrix does not use External Reference Median Normalization (uses Cross-Plate Internal Median Normalization instead)
> * MultiMatrix uses PlatformSpecificQCCheckTailPercent (at plate level) instead of PlatformSpecificCalibrateTailPercent

## SOMAmer Level Metrics

SOMAmer level metrics are found in the SOMAmer/column-level metadata in the ADAT.

<table><thead><tr><th width="290.765625">Metric</th><th>ADAT Field</th><th>Applies To (Kit Type)</th></tr></thead><tbody><tr><td>Platform Specific Calibration</td><td>PlatformSpecificCalibrate_&#x3C;PlateBarcode>_ScaleFactor</td><td>Plasma, Serum, CSF</td></tr><tr><td>Cross Platform Calibration</td><td>CrossPlatformCalibrate_&#x3C;PlateBarcode>_ScaleFactor</td><td>Plasma, Serum, CSF</td></tr><tr><td>QC Check</td><td>QCCheck_&#x3C;PlateBarcode>_ScaleFactor</td><td>Plasma, Serum, CSF</td></tr><tr><td>Platform Specific QC Check</td><td>PlatformSpecificQCCheck_&#x3C;PlateBarcode>_ScaleFactor</td><td>MultiMatrix</td></tr></tbody></table>

## Plate Level Metrics

Plate level metrics are found in the header metadata in the ADAT.

| Metric                                  | ADAT Field                                                                           | Applies To (Kit Type)                                | Threshold                                          | Impact to Plate |
| --------------------------------------- | ------------------------------------------------------------------------------------ | ---------------------------------------------------- | -------------------------------------------------- | --------------- |
| QC Percent in Tails                     | QCCheckTailPercent; QCCheckTailPercent\_PassFlag                                     | Plasma, Serum, CSF                                   | QCCheckTailPercent < 15%                           | PASS/FAIL       |
| Calibration Percent in Tails            | PlatformSpecificCalibrateTailPercent; PlatformSpecificCalibrateTailPercent\_PassFlag | Plasma, Serum, CSF                                   | PlatformSpecificCalibrateTailPercent < 15%         | PASS/WARNING    |
| QC Check Percent in Tails (MultiMatrix) | PlatformSpecificQCCheckTailPercent; PlatformSpecificQCCheckTailPercent\_PassFlag     | MultiMatrix                                          | PlatformSpecificQCCheckTailPercent < 15%           | PASS/WARNING    |
| SOMAmer Normalized Reads                | PlateSOMAmerNormReads\_PassFlag                                                      | All kits                                             | < 70% of blank samples flagged at SOMAmerNormReads | PASS/WARNING    |
| Platform Specific Plate Scale           | PlatformSpecificPlateScale\_ScaleFactor                                              | All kits                                             | N/A                                                | N/A             |
| Cross Platform Plate Scale              | CrossPlatformPlateScale\_ScaleFactor                                                 | All kits                                             | N/A                                                | N/A             |
| Cross Platform Calibration              | CrossPlatformCalibrationTailPercent                                                  | Plasma, Serum, CSF                                   | N/A                                                | N/A             |
| IntraPlateMedianCV                      | IntraPlateMedianCV                                                                   | All kits (Plasma/Serum/CSF: Cal+QC; MultiMatrix: QC) | N/A                                                | Informational   |
| InterPlateMedianCV                      | InterPlateMedianCV                                                                   | Plasma, Serum, CSF (requires ≥4 plates)              | N/A                                                | Informational   |
| MedianS2B                               | MedianS2B                                                                            | All kits (Plasma/Serum/CSF: Cal+QC; MultiMatrix: QC) | N/A                                                | Informational   |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://help.multiomics.illumina.com/dragen-protein-quantification/counting-and-normalization/metrics-appendix.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
